Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38626902

RESUMO

BACKGROUND: The benefits of minimally invasive techniques in cardiac surgery remain poorly defined. We evaluated the short- and mid-term outcomes after surgical aortic valve replacement through partial upper versus complete median sternotomy (MS) in a large, German multicenter cohort. METHODS: A total of 2,929 patients underwent isolated surgical aortic valve replacement via partial upper sternotomy (PUS, n = 1,764) or MS (n = 1,165) at nine participating heart centers between 2016 and 2020. After propensity-score matching, 1,990 patients were eligible for analysis. The primary end point was major adverse cardiac and cerebrovascular events (MACCE), a composite of death, myocardial infarction, and stroke at 30 days and in follow-up, up to 5 years. Secondary end points were acute kidney injury, length of hospital stay, transfusions, deep sternal wound infection, Dressler's syndrome, rehospitalization, and conversion to sternotomy. RESULTS: Unadjusted MACCE rates were significantly lower in the PUS group both at 30 days (p = 0.02) and in 5-year follow-up (p = 0.01). However, after propensity-score matching, differences between the groups were no more statistically significant: MACCE rates were 3.9% (PUS) versus 5.4% (MS, p = 0.14) at 30 days, and 9.9 versus 11.3% in 5-year follow-up (p = 0.36). In the minimally invasive group, length of intensive care unit (ICU) stay was shorter (p = 0.03), Dressler's syndrome occurred less frequently (p = 0.006), and the rate of rehospitalization was reduced significantly (p < 0.001). There were 3.8% conversions to full sternotomy. CONCLUSION: In a large, German multicenter cohort, MACCE rates were comparable in surgical aortic valve replacement through partial upper and complete sternotomies. Shorter ICU stay and lower rates of Dressler's syndrome and rehospitalization were in favor of the partial sternotomy group.

2.
J Cardiothorac Vasc Anesth ; 38(3): 649-659, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38228424

RESUMO

OBJECTIVE: To verify the impact of preoperative levosimendan on patients with severe left ventricular dysfunction (ejection fraction <35%) undergoing isolated coronary artery bypass grafting. DESIGN: A meta-analysis. SETTING: Hospitals. PARTICIPANTS: The authors included 1,225 patients from 6 randomized controlled trials. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The authors performed a meta-analysis of trials that compared preoperative levosimendan with placebo or no therapy, reporting efficacy and safety endpoints. Statistical analyses used mean differences and risk ratios (RR), with a random effects model. Six studies were included, comprising 1,225 patients, of whom 615 (50.2%) received preoperative levosimendan, and 610 (49.8%) received placebo/no therapy. Preoperative levosimendan showed a lower risk of all-cause mortality (RR 0.31; 95% CI 0.16-0.60; p < 0.01; I2 = 0%), postoperative acute kidney injury (RR 0.44; 95% CI 0.25-0.77; p < 0.01; I2 = 0%), low-cardiac-output syndrome (RR 0.45; 95% CI 0.30-0.66; p < 0.001; I2 = 0%), and postoperative atrial fibrillation (RR 0.49; 95% CI 0.25-0.98; p = 0.04; I2 = 85%) compared to control. Moreover, levosimendan significantly reduced the need for postoperative inotropes and increased the cardiac index at 24 hours postoperatively. There were no differences between groups for perioperative myocardial infarction, hypotension, or any adverse events. CONCLUSION: Preoperative levosimendan in patients with severe left ventricular dysfunction undergoing isolated coronary artery bypass grafting was associated with reduced all-cause mortality, low-cardiac-output syndrome, acute kidney injury, postoperative atrial fibrillation, and the need for circulatory support without compromising safety.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Simendana , Disfunção Ventricular Esquerda , Humanos , Injúria Renal Aguda/etiologia , Fibrilação Atrial/etiologia , Baixo Débito Cardíaco/tratamento farmacológico , Baixo Débito Cardíaco/etiologia , Cardiotônicos/uso terapêutico , Ponte de Artéria Coronária/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/tratamento farmacológico , Ensaios Clínicos Controlados Aleatórios como Assunto , Simendana/uso terapêutico
3.
Biomolecules ; 13(7)2023 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-37509127

RESUMO

One of the contributors to atherogenesis is enzymatically modified LDL (eLDL). eLDL was detected in all stages of aortic valve sclerosis and was demonstrated to trigger the activation of p38 mitogen-activated protein kinase (p38 MAPK), which has been identified as a pro-inflammatory protein in atherosclerosis. In this study, we investigated the influence of eLDL on IL-6 and IL-33 induction, and also the impact of eLDL on calcification in aortic valve stenosis (AS). eLDL upregulated phosphate-induced calcification in valvular interstitial cells (VICs)/myofibroblasts isolated from diseased aortic valves, as demonstrated by alizarin red staining. Functional studies demonstrated activation of p38 MAPK as well as an altered gene expression of osteogenic genes known to be involved in vascular calcification. In parallel with the activation of p38 MAPK, eLDL also induced upregulation of the cytokines IL-6 and IL-33. The results suggest a pro-calcifying role of eLDL in AS via induction of IL-6 and IL-33.


Assuntos
Estenose da Valva Aórtica , Calcinose , Humanos , Valva Aórtica/patologia , Estenose da Valva Aórtica/metabolismo , Interleucina-6/genética , Interleucina-6/metabolismo , Esclerose/metabolismo , Esclerose/patologia , Interleucina-33/genética , Interleucina-33/metabolismo , Calcinose/metabolismo , Células Cultivadas , Proteínas Quinases p38 Ativadas por Mitógeno/genética , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
4.
BioData Min ; 16(1): 12, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36927544

RESUMO

BACKGROUND: Automated data analysis and processing has the potential to assist, improve and guide decision making in medical practice. However, by now it has not yet been fully integrated in a clinical setting. Herein we present the first results of applying algorithm-based detection to the diagnosis of postoperative acute kidney injury (AKI) comprising patient data from a cardiac surgical intensive care unit (ICU). METHODS: First, we generated a well-defined study population of cardiac surgical ICU patients by implementing an application programming interface (API) to extract, clean and select relevant data from the archived digital patient management system. Health records of N = 21,045 adult patients admitted to the ICU following cardiac surgery between 2012 and 2022 were analyzed. Secondly, we developed a software functionality to detect the incidence of AKI according to Kidney Disease: Improving Global Outcomes (KDIGO) criteria, including urine output. Incidence, severity, and temporal evolution of AKI were assessed. RESULTS: With the use of our automated data analyzing model the overall incidence of postoperative AKI was 65.4% (N = 13,755). Divided by stages, AKI 2 was the most frequent maximum disease stage with 30.5% of patients (stage 1 in 17.6%, stage 3 in 17.2%). We observed considerable temporal divergence between first detections and maximum AKI stages: 51% of patients developed AKI stage 2 or 3 after a previously identified lower stage. Length of ICU stay was significantly prolonged in AKI patients (8.8 vs. 6.6 days, p <  0.001) and increased for higher AKI stages up to 10.1 days on average. In terms of AKI criteria, urine output proved to be most relevant, contributing to detection in 87.3% (N = 12,004) of cases. CONCLUSION: The incidence of postoperative AKI following cardiac surgery is strikingly high with 65.4% when using full KDIGO-criteria including urine output. Automated data analysis demonstrated reliable early detection of AKI with progressive deterioration of renal function in the majority of patients, therefore allowing for potential earlier therapeutic intervention for preventing or lessening disease progression, reducing the length of ICU stay, and ultimately improving overall patient outcomes.

5.
Ann Cardiothorac Surg ; 11(6): 596-604, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36483620

RESUMO

Background: Following the first robotic-assisted mitral valve operations in Paris and Leipzig, the era of this innovative technique expired after a few years in Germany. At that time, the main arguments against robotic surgery within the German cardiac surgical community were low cost effectiveness and operative time utilization. Encouraged by favorable results, we re-started our robotic-assisted cardiac program as the first and only center in Germany in 2019. Methods: Between July 2019 and December 2021, 329 patients underwent robotic-assisted operations using the daVinci Xi system, including mitral and coronary operations, myxoma resection, atrial septal closure and stand-alone atrial ablation. Of these, 182 patients underwent mitral valve repair (MVR). Isolated MVR was performed in 96 patients (isolated mitral group, IMG) and 86 underwent concomitant operations, such as tricuspid valve repair, Cox-Maze IV, pulmonary vein isolation (PVI) and left atrial appendage (LAA) closure (complex mitral group, CMG). For cost analysis, the InEK calculation for 2020 was used. Results: MVR was successful (MR ≤I°) in all patients. Patients in the IMG had a hospital mortality of 1.0% (O/E ratio 0.69) and stroke rate of 2.0%. Four patients (4.0%) required conversion to sternotomy and 6 patients (6.0%) needed re-exploration for bleeding. Mortality was 3.5% (O/E ratio 0.74) in the CMG and stroke rate 2.3%. The conversion and bleeding rates were 4.6% each, respectively. The steep learning curve resulted in significant reduction of operating times greater than 25% in the IMG. Comparing the results of robotic-assisted procedures to minimally-invasive mitral surgeries (MIMS) in 2020, a reduction in length of hospital stay of almost 25% resulted in significantly lower costs for the medical service and medical infrastructure. However, within the German health service, overall cost for robotic-assisted procedures were more expensive compared to MIMS by 5% due to higher material costs. Conclusions: The re-establishment of robotic mitral valve surgery in Germany was successful with comparable results to MIMS in terms of mortality and morbidity. Robotic-assisted cardiac operations resulted in accelerated postoperative recovery with significant shortening of the hospital length of stay. The avoidance of liver injury is one focus for the future.

6.
Thorac Cardiovasc Surg ; 70(8): 623-629, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35038756

RESUMO

OBJECTIVE: Surgery of acute aortic dissection using the frozen elephant trunk (FET) can be complicated when the origin of the left subclavian artery (LSA) is dissected and sacrifice by ligation is a viable option. However, the LSA is supposed to play a role in neuroprotection as a major collateral. We, therefore, analyzed our results of LSA sacrifice in this cohort. METHODS: We identified a total of 84 patients from our prospectively collected database who underwent FET repair of acute aortic dissection between October 2009 and April 2018. LSA was sacrificed in 19 patients (22.6%). Results were analyzed and compared with regard to neurological outcomes. RESULTS: New postoperative stroke was seen in two patients (2.4%) and spinal cord injury in three patients (3.6%) overall, none in the LSA-sacrifice group. We observed a temporary neurological deficit in five patients (6.0%) overall, none in the LSA-sacrifice group. None of the patients developed acute ischemia of the left arm. Only two patients (12.5%) came back for carotid-subclavian artery bypass due to exertion-induced weakness of the left arm 3 to 4 months after the initial surgery. In-hospital mortality was 15.5% overall, with no difference between groups. CONCLUSION: LSA sacrifice was not associated with elevated postoperative risk of either central or spinal neurological injury. Thus, it can facilitate FET repair of acute aortic dissection in selected cases when the left subclavian origin cannot be preserved. Carotid-subclavian artery bypass became necessary in only a small fraction of these patients and can be performed as a second-stage procedure.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Artéria Subclávia/cirurgia , Stents , Resultado do Tratamento , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Procedimentos Endovasculares/métodos
7.
J Cardiovasc Surg (Torino) ; 62(1): 87-94, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32909704

RESUMO

BACKGROUND: Minimally invasive access via partial sternotomy has been established for aortic valve surgery in the past years. But concomitant procedures like atrial ablation and aortic valve replacement via partial upper sternotomy have not been investigated so far. We therefore present our operative technique and results in terms of safety and efficacy, including follow-up and quality of life. METHODS: Between February 2007 and March 2014 a total of 67 patients undergoing isolated minimally invasive aortic valve replacement received concomitant left atrial ablation at our centre. Operative technique and short- and midterm results are described, including quality of life assessment using the SF-36 questionnaire. RESULTS: Operative techniqual success rate was 98.5%. We observed only one (1.5%) ablation-related conversion to full sternotomy. Operative times, reexploration and stroke rates as well as 30-day mortality are comparable to open procedures. Efficacy: The proportions of patients in sinus rhythm at discharge was 54.5% for paroxysmal AF patients and 27.7% overall. After a mean follow-up time of 38.0±22.6 months the cardiac related mortality rate was 4.5%, the rate of sinus rhythm was 72.7% for paroxysmal AF patients and 36.8% overall. Of survivors, overall mean quality of life was 7.3±2.1 as measured by SF-36. CONCLUSIONS: Concomitant left atrial ablation and aortic valve replacement can safely be performed via partial sternotomy and results are non-inferior to open surgery.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fibrilação Atrial/cirurgia , Implante de Prótese de Valva Cardíaca , Procedimento do Labirinto , Esternotomia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Procedimento do Labirinto/efeitos adversos , Procedimento do Labirinto/mortalidade , Complicações Pós-Operatórias/mortalidade , Qualidade de Vida , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Ann Cardiothorac Surg ; 9(3): 178-188, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32551250

RESUMO

BACKGROUND: Over the years, frozen elephant trunk (FET) has become the treatment of choice for multisegmental thoracic aortic disease. This multicenter study presents the evolution of FET results using the E-vita Open hybrid graft with respect to institutional experience and time. METHODS: The data of International E-vita Open registry were studied according to the institutional experience of the participating centers (high- versus low-volume centers) and according to the evolution of FET treatment during time (1st period, 2005-2011 versus 2nd period, 2012-2018). Overall, 1,165 patients were enrolled in the study with a wide variety of multisegmental thoracic aortic pathologies and aortic emergencies. Participating centers determined their own surgical protocol. RESULTS: The overall 30-day mortality was 12%. Short- and long-term survival were higher in high- versus low-volume centers (P=0.048 and P=0.013, respectively). In the 2nd time period, cerebral complications were reduced significantly (P=0.015). Incidence of permanent spinal cord-related symptoms was reduced to 3% in the 2nd time period, but did not reach statistical significance. Hypothermic circulatory arrest time (P<0.001) and incidence of postoperative temporary renal replacement therapy (P=0.008) were significantly reduced in the 2nd time period. Ten-year survival and freedom from aortic-related death rates were 46.6% and 85.7%, respectively, for the entire group. The freedom from distal aortic re-interventions for a new or progressive residual aortic disease was 76.0%. CONCLUSIONS: Evolution of FET arch repair techniques with the E-vita Open graft and increasing institutional experience were associated with improved results. Progression of residual aortic disease makes close follow-up with aortic imaging mandatory in such patients.

9.
Thorac Cardiovasc Surg Rep ; 9(1): e21-e23, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32461876

RESUMO

Background Patients presenting with several cardiothoracic conditions that need to be addressed surgically require individual decision making as evidence remains inconclusive and combined surgical procedures carry an elevated perioperative risk. Case Description We present the case and management of a 73-year-old male with myocardial infarction due to three-vessel disease and left main stem stenosis, calcified aortic aneurysm, and right-sided non-small cell lung carcinoma. Conclusion High-risk combined surgery should be indicated with scrutiny after individual consideration by an experienced heart team.

10.
Thorac Cardiovasc Surg ; 67(5): 372-378, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30060269

RESUMO

BACKGROUND: Valve sparing aortic root repair by reimplantation (David procedure) is an established technique in acute aortic dissection Stanford type A involving the aortic root. In DeBakey type I dissection, aortic arch replacement using the frozen elephant trunk (FET) was introduced to promote aortic remodeling of the downstream aorta. The combination of these two complex procedures represents a challenging surgical strategy and was considered too risky so far. METHODS: All patients with acute aortic dissection DeBakey type I undergoing valve sparing aortic root repair by reimplantation technique of David combined with extended aortic repair using the FET at our center between October 2009 and December 2016 were evaluated. Outcomes are compared with patients who underwent prosthetic aortic root replacement and FET for aortic dissection in the same timeframe. RESULTS: A total of 28 patients received combined David and FET procedure, while 20 patients received prosthetic aortic root replacement and FET procedure. Thirty-day mortality was 10.7% (n = 3) for the David group and 20% (n = 4) for the root replacement group (p = 0.43). Postoperative echocardiographic control revealed an excellent aortic valve function with regurgitation grade 0° or maximum grade I° and a mean gradient of 4.3 ± 2.1 mm Hg in all patients in the David group versus 7.2 ± 2.4 mm Hg in the aortic root replacement group, p = 0.003. Computed tomography angiography scan showed positive aortic remodeling in all but three patients (91.9%). Mid-term follow-up survival was 82.1% in the David group and 68.4% in the root replacement group, p = 0.28. There was no need for reintervention at the root or descending aorta. CONCLUSION: Simultaneous application of the David and FET procedure in patients with acute aortic dissection is safe and feasible in experienced hands as compared with standard aortic root replacement plus FET. The mid-term outcomes are encouraging and noninferior to conventional surgery results.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Cirúrgicos Cardíacos/métodos , Reimplante , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Recuperação de Função Fisiológica , Reimplante/efeitos adversos , Reimplante/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Thorac Dis ; 10(7): 4195-4203, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30174864

RESUMO

BACKGROUND: The extent of emergent surgery for acute DeBakey type I aortic dissection is discussed controversial. The frozen elephant trunk (FET) technique in addition to ascending and arch repair promotes aortic remodelling in the descending aorta and thus may provide superior long-term results in terms of less secondary re-interventions and reduced mortality linked to the downstream aorta. METHODS: Between October 2009 and December 2016, a total of 72 patients underwent emergent hybrid aortic repair using the FET for acute DeBakey type I aortic dissection at our centre. Data were analysed from our prospectively collected database and clinical and imaging mid-term follow-up was obtained. RESULTS: Implant success was 98.6% with an overall 30-day-mortality of 15.3%. New postoperative stroke was seen in 2.8%, new spinal cord injury in 4.2%. In follow-up (mean 37.8±21.2 months) cumulative survival was 75.0% with freedom from distal reintervention in 96.7% and aortic remodelling rate in the descending aorta in 96.5%. CONCLUSIONS: Hybrid aortic repair using the FET in acute DeBakey type I aortic dissection does not elevate the perioperative risk of mortality and provides excellent aortic remodelling with low distal re-intervention rate in mid-term follow-up.

12.
Innovations (Phila) ; 12(5): 351-355, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28759544

RESUMO

OBJECTIVE: Median sternotomy is still the standard approach for aortic arch surgery. Minimally invasive techniques promise faster recovery with shorter hospital stay due to thoracic stability, reduced pain, and superior cosmetic results. However, safety is a concern in complex aortic surgery. The aim of our study was to demonstrate that aortic arch surgery via partial upper sternotomy is viable, safe, and equivalent to standard procedure both in terms of its safety and the risk of major adverse cardiac and cerebrovascular events. METHODS: We interrogated our prospectively collected database and identified a total of 21 nonemergent patients operated on at our center between October 2008 and February 2015. Indication for operation was aneurysmatic disease in 18 and aortic dissection in 3 patients. Data were analyzed for in-hospital mortality, stroke, bleeding complications, and acute kidney injury. RESULTS: Mean ± standard deviation age of patients was 69.3 ± 14.4 years, 57.1% were female, and mean ± standard deviation logistic EuroSCORE was 17.0 ± 7.2%. Surgery on the aortic arch comprised proximal arch in 9, hemiarch in 9, and total arch replacement plus frozen elephant trunk in 3 patients. Concomitant procedures included aortic root repair in 10, aortic root replacement in 2, and aortic valve replacement in 3 patients. We lost one patient because of septic shock, no stroke occurred, but a transient neurologic deficit in three and a postoperative delirium in four patients. Re-exploration for bleeding was necessary in two patients, and one patient had acute kidney injury. CONCLUSIONS: Minimally invasive aortic arch surgery via partial upper sternotomy does not increase the risk of morbidity or mortality. Thus, in experienced hands, it is viable, safe, and therefore favorable and as a result should be offered to more patients.


Assuntos
Aorta Torácica/cirurgia , Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Esternotomia/métodos , Injúria Renal Aguda/complicações , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Hemorragia/complicações , Hemorragia/epidemiologia , Hemorragia/cirurgia , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Esternotomia/normas , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/epidemiologia
13.
Eur J Cardiothorac Surg ; 52(2): 310-318, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575324

RESUMO

OBJECTIVES: The frozen elephant trunk (FET) technique allows one-stage hybrid repair approach in aortic dissection (AoD). Even if the effect of the FET technique on promoting false lumen (FL) thrombosis has been proved in the past, the relative importance of FL thrombosis on aortic remodelling at different levels of the distal aorta and the magnitude of this effect is not well known. The aim of the study was to evaluate aortic remodelling following a FET technique for AoD. METHODS: A multicentre international registry database was searched to identify all patients who underwent a FET procedure for an AoD. A total of 383 patients with AoD were operated on between January 2005 and March 2014 with the FET technique; 137 patients (65 acute AoD and 72 chronic AoD) who survived the initial repair with at least a 1-year follow-up CT scan were included in the study. RESULTS: The rate of FL thrombosis was higher in the mid-descending thoracic aorta (99.3%) and lower in the distal abdominal aorta (13.9%) but similar between acute and chronic AoDs. The negative remodelling rate was similar between acute and chronic AoDs in the abdominal aorta, but chronic AoD exhibited a higher rate of negative remodelling in the descending thoracic aorta (33% vs 17.5%, P = 0.040). CONCLUSIONS: The FET technique provides an effective treatment for AoD, promoting FL thrombosis and remodelling in the descending thoracic aorta. Changes in the diameter of the aortic lumen depend mainly on the status of the FL and are similar between acute and chronic AoD. Changes in the diameter of true lumen are affected by both the FL status and the timing of the presentation. However, increased FL thrombosis and positive remodelling rates are not maintained at the level of the abdominal aorta, and strict follow-up is mandatory to detect early changes in the aortic dimensions, which may warrant further interventions.


Assuntos
Aorta , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Idoso , Aorta/patologia , Aorta/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos
14.
J Heart Valve Dis ; 25(1): 112-113, 2016 01.
Artigo em Inglês | MEDLINE | ID: mdl-27989095

RESUMO

Reoperations after the Ross procedure are rare, with autograft as well as homograft failure being the dominant causes for redo cardiac procedures. Due to increasing experience with valve-sparing aortic valve procedures, more valves can be preserved during redo surgery. Herein are reported the details of a patient who underwent quadruple valve reoperation comprising redo with a reconstructive approach after the short-term failure of pulmonary autograft and homograft with concomitant mitral and tricuspid regurgitation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Bioprótese/efeitos adversos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Reoperação , Transplante Autólogo/efeitos adversos , Transplante Homólogo/efeitos adversos , Resultado do Tratamento
15.
J Heart Valve Dis ; 24(5): 635-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26897844

RESUMO

BACKGROUND AND AIM OF THE STUDY: Transcatheter procedures are considered the therapy of choice for high-risk patients who are not eligible for surgical aortic valve replacement. Although its utility is debated, the logistic EuroSCORE I is still the most frequently used risk calculator for cardiac surgery in Europe, and was used in the present study to identify patients with an extremely high risk of predicted perioperative mortality. METHODS: This single-centre study included 319 consecutive patients who underwent transapical or transaortic transcatheter aortic valve implantation (TAVI) between September 2008 and December 2012. Combined hybrid procedures and transfemoral TAVI patients were excluded. Those patients predicted to have an excessively high risk of perioperative mortality (EuroSCORE >40%, n = 90) were compared to those with a lower calculated risk (EuroSCORE <40%, n = 229) with respect to perioperative complications, short-term-mortality and major adverse cardiac and cerebrovascular events. RESULTS: The 30-day mortality was 12.2% (n = 11) in the extremely high-risk group, and 6.6% (n = 15) in the lower-risk group (p = 0.08). There were no significant differences in the stroke rate (3.3% versus 0.4%, p = 0.07) or the incidence of acute kidney injury stage 3 (11.1% versus 5.2%, p = 0.32). The establishment of cardiopulmonary bypass (3.9% versus 11.1%, p = 0.02), conversion to sternotomy (1.3% versus 5.6%, p = 0.04), mean ventilation time (15.2 h versus 43.5 h, p = 0.007) and length of intensive care unit stay (2.9 days versus 6.8 days, p <0.001) were all significantly lower in the lower-risk group. CONCLUSION: The data acquired verified that TAVI is a safe procedure, even in patients with an extremely high predicted risk of perioperative mortality and major adverse cardiac and cerebrovascular events. Furthermore, the analysis substantiated the need for individualized risk evaluation.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Estimativa de Kaplan-Meier , Tempo de Internação , Modelos Logísticos , Masculino , Razão de Chances , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
16.
Interact Cardiovasc Thorac Surg ; 20(4): 558-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25538252

RESUMO

Persistent left superior vena cava draining into the left atrium is a rare congenital venous anomaly, which remains asymptomatic and therefore undetected in most cases. Paradoxical embolization caused by right-to-left shunt is a severe complication and requires surgical correction. We describe the first thoracoscopic approach for ligation of a persistent left superior vena cava even though our patient had severe kyphoscoliosis because of Klippel-Feil syndrome.


Assuntos
Toracoscopia , Malformações Vasculares/cirurgia , Veia Cava Superior/cirurgia , Humanos , Síndrome de Klippel-Feil/complicações , Síndrome de Klippel-Feil/diagnóstico , Cifose/diagnóstico , Cifose/etiologia , Ligadura , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Escoliose/diagnóstico , Escoliose/etiologia , Toracotomia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Malformações Vasculares/complicações , Malformações Vasculares/diagnóstico , Veia Cava Superior/anormalidades , Veia Cava Superior/diagnóstico por imagem
17.
Ann Thorac Surg ; 96(2): 507-12, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23773729

RESUMO

BACKGROUND: Chronic kidney disease is a significant risk factor for mortality as well as acute kidney injury in cardiac surgery. The impact of contrast agent application on outcome is not well described in patients undergoing transcatheter aortic valve implantation. METHODS: We analyzed data of 270 patients who underwent transcatheter aortic valve implantation (TAVI) between September 2008 and March 2012. Acute kidney injury was defined according to modified risk, injury, failure, loss and end-stage renal failure criteria. Patients on chronic hemodialysis were analyzed separately (n = 15). In 129 (47.8%) patients chronic kidney disease was apparent preoperatively. On average, 83.7 (± 32.4) mL of contrast agent were used per patient. RESULTS: Postoperatively, 41 patients (15.2%) developed acute kidney injury. In 19 patients (7.1%) transient renal replacement therapy was necessary; no chronic hemodialysis was required. Thirty-day-mortality did not differ between patients with or without chronic kidney disease (7.0% vs 7.1%, p = 0.97). Additionally, chronic kidney disease had no influence on the incidence of postoperative acute kidney injury (12.8% vs 20.2%, p = 0.07) or postoperative hemodialysis (5.0% vs 10.5%, p = 0.08). No correlation between the amount of contrast agent applied and the incidence of acute kidney injury could be verified (p = 0.57). CONCLUSIONS: Preoperative chronic kidney disease does not increase the risk of mortality and acute kidney injury after transcatheter aortic valve implantation. Acute kidney injury after TAVI is associated with an elevated risk of mortality. The amount of contrast agent applied intra-procedurally does not affect the risk of acute kidney injury.


Assuntos
Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/mortalidade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/fisiopatologia , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
18.
J Vasc Interv Radiol ; 22(4): 563-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21463760

RESUMO

The authors report two cases of stent-assisted embolization (SAE) in the aorta. In one case, SAE was performed for treatment of a pseudoaneurysm; the procedure consisted of stent placement and embolization with an AMPLATZER Vascular Plug and detachable coils through the stent struts. In the second case, SAE was performed to stop acute bleeding from an aortoureteral fistula. Before SAE in this case, the aortic bifurcation was reconstructed with self-expandable and balloon-expandable stents. SAE was technically successful in both cases. SAE for aortic pathologic processes may be useful in selected cases as an alternative to surgery or endovascular stent-graft therapy.


Assuntos
Falso Aneurisma/terapia , Aneurisma Aórtico/terapia , Embolização Terapêutica/instrumentação , Stents , Doenças Ureterais/terapia , Fístula Urinária/terapia , Fístula Vascular/terapia , Idoso , Falso Aneurisma/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Masculino , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Doenças Ureterais/complicações , Doenças Ureterais/diagnóstico por imagem , Fístula Urinária/complicações , Fístula Urinária/diagnóstico por imagem , Fístula Vascular/complicações , Fístula Vascular/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA